Equipment model | Semco SI BCDS-V 100V 100A-1CH |
Communication | TCP/IP (so) |
Channel control | Single point independent control |
Charging | 80% |
Charging voltage | 0 ~ 100 v |
Port discharge | 12.5 ~ 100V |
Charging current | 0.02 A ~ 100 A |
Discharge | 75% |
Discharge current | 0.1 A ~ 100 A |
Voltage accuracy | ± (0.05%RD + 0.05%FS) |
Accuracy of | ± (0.1%RD + 0.05%FS) |
Main | According to the specific equipment, it can be customized and equipped with 1 channel for each |
Voltage | 1mV |
Current | 1mA |
Temperature resolution | 0.1 ℃ |
The input power | AC 220V±10%/50Hz (Power supply mode for cabinet: three-phase five-wire) |
Sampling time | Sampling frequency of a single box is 10mS |
Recording time | 100mS~65535S |
Charging mode | Constant-current voltage limiting, constant-current voltage, constant-power charging, constant-current charging test (for batteries with protection plates) |
Charge cut-off condition | Voltage, current, time, capacity, temperature |
Discharge patterns | Constant current discharge, constant power discharge, constant current discharge test (for batteries with protection plates) |
Discharge cut-off
condition |
Voltage, current, time, capacity, temperature |
Number of working steps per cycle | 100 steps with nested loops (10 layers) |
Circuit structure | Modular design for easy replacement and maintenance |
Software and hardware
protection |
Reverse connection protection, over voltage protection, over current protection, over temperature protection, under voltage protection, short circuit
protection |
Main System Functions |
The software supports all kinds of continuation, such as manual suspension, software shutdown continuation, power interruption continuation, equipment communication interruption continuation, abnormal stop continuation.
Support bar code scanning, can scan one-dimensional code, two-dimensional code, sequence scanning, channel hopping scanning, disk scanning and other scanning methods. Local test detailed data storage, you can view the current test data and historical data of each channel at any time, data and curve corresponding two ways to present, and support to export EXCE report in the form of single or batch, in addition, according to the need to set the automatic derivative data at the end of the test. Support capacity sorting, can be graded battery sorting and LED light. Support the Pass judgment at the end of the test, according to the specified cycle capacity, voltage, time and other information to judge the Pass/NG result. Support all kinds of working step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, over discharge protection test. Support unit conversion Support database server background MES storage or other MES docking Offline protection of hardware and software. Support channel parallel function Voltage acquisition and real-time screening, check the battery crimp before the test, and turn into voltage screening after the test. BMS communication protocol is connected, and battery charging and discharging steps are monitored through BMS data items. |